Unisensor – Rapid Test for Dairy

Unisensor improves food safety with screening solutions to detect antibiotics, mycotoxins and food fraud in Dairy, Cereals, Honey, Feed, Meat and Sea food ingredients.

For over 15 years, Unisensor has been developing rapid tests for the analysis of various food products.Products are based on the Lateral Flow Chromatography and present common features like:

• Competitive Assay in Dipstick Format

• Results in a Very Short Time

• Clear Visual Interpretation

• Adapted for Unisensor’s Versatile Equipment

• Contain Positive and Negative Standards

• Pipet, Tips and Kit certificate are included

Some of the products target individual compounds while the others allow simultaneous detection of all compounds from a single family or from several families at a time

ANTIBIOTICS

SINGLE TESTS


BETAXPRESS (REF. KIT044)

• Generic for all ß-lactam compounds

• Most drugs at or below MRL

• 3 minutes at °45C


TETRASENSOR (REF. KIT014)

• Generic for all Tetracycline compounds

• Most drugs at or below MRL

• 10 minutes at Room Temperature


SULFASENSOR (REF. KIT039)

• Generic for all Sulfonamide compounds

• Most drugs at or below MRL

• 6 minutes at °40C


QUINOSENSOR (REF. KIT038)

• Generic for all Quinolone compounds

• Most drugs at or below MRL

• 6 minutes at °40C


CAPSENSOR (REF. KIT040)

• Specific for Chloramphenicol

• Limit of Detection at 0,3 ppb

• 6 minutes at °40C


TYLOSENSOR (REF. KIT049)

• Specific for Tylosine

• Limit of Detection below MRL (50ppb)

• 6 minutes at °40C


NEOSENSOR (REF. KIT045)

• Specific for Neomycine

• Limit of Detection below MRL (1500 ppb)

• 6 minutes at °40C


STREPTOSENSOR (REF. KIT046)

• Specific for Streptomycin and DH-Strepto

• Limit of Detection at MRL (200 ppb)

• 6 minutes at °40C


GENTASENSOR (REF. KIT047)

• Specific for Gentamycin

• Limit of Detection below MRL (200)

• 6 minutes at °40C

ANTIBIOTICS

MULTIPLE TESTS

X2


TWINSENSOR (REF. KIT020 (*) REF. KIT034 (** )

•Generic for all ß-lactams and Tetracyclines

• Most drugs at or below MRL

• 6 minutes at °40C


(*) Kit020: EU Regulation – (**) Kit034: Russian Regulation

TWINSENSOR ROOM TEMPERATURE (REF. KIT088)

•Generic for all ß-lactams and Tetracyclines

• Most drugs at or below MRL

• 10 minutes at Room Temperature

X3


TRISENSOR (REF. KIT035)

•Generic for all ß-lactams, sulfonamides and Tetracyclines

• Most drugs at or below MRL

• 6 minutes at °40C


3AMINOSENSOR (REF. KIT048)

•Specific for Neomycin, Streptomycin, Dihydrostreptomycin, Gentamycin and Paromycin compounds

• Most drugs at or below MRL

• 6 minutes at °40C

X4


4AMINOSENSOR (REF. KIT068)

•Specific for Neomycin, Streptomycin, Dihydrostreptomycin, Gentamycin, Kanamycin, Paromycin and Apramycin compounds

• Most drugs at or below MRL

• 6 minutes at °40C


4SENSOR (BSCT) (REF. KIT060)

•Specific for all ß-lactams,Tetracyclines, Streptomycin and Chloramphenicol compounds

• All drugs at the Russian MRL

• 10 minutes at °40C

X4


4SENSOR (BSTQ) (REF. KIT072)

•Specific for all ß-lactams, Sulfonamides, Tetracyclines, and Quinolones compounds

• All drugs at the EU MRL

• 6 minutes at °40C


ADULTERATION

SINGLE TESTS

COWSENSOR  (REF. KIT037)

•Specific for Cow milk Identification

• Limit at %0,5

•10 minutes at Room Temperature


GOATSENSOR (REF. KIT043)

•Specific for Goat milk Identification

• Limit at %1

•10 minutes at °40C


MELASENSOR (REF. KIT083)

•Specific for Melamine milk adulteration

• Limit of Detection at 50ppb

• 5 minutes at °40C

TOXINS

SINGLE TESTS

AFLASENSOR QUANTI (REF. KIT041 (*) REF. KIT078 (**) )

• Specific for Aflatoxin M1

•Quantitative results ranging from 20 ppt to 750 ppt

•10 minutes at °40C


(*) Kit041: EU Regulation – (**) Kit078: US Action Level (SL)

EQUIPMENT

Fast and accurate results require the use of instrumentation manufactured by Unisensor.
Both HEATSENSOR® and READSENSOR® work for all our products.

HEATSENSOR® DUO REF. APP032 HEATSENSOR® OCTO REF. APP052

Adapted to perform One Step Test Procedure for all our Products.

AT A GLANCE

  • • Automatic release of dipstick
    • Versatile equipment for all Products
    • DUO is for maximum 2 tests at a time • OCTO is for maximum 8 tests at a time • Self-timing with light and audio signal • Product’s specific program included
    • Easy to use

READSENSOR® REF. APP-038APP039

The READSENSOR® is a hand held instrument for optical measurement of developed dipsticks.

The READSENSOR® interprets on a semi- quantitative or quantitative based algorithm.

The READSENSOR® provides objectivity and convenience for the operator.

AT A GLANCE

  • Clear rapid and accurate interpretation of results
  • Results can be displayed, printed, stored or transferred to USB upon request
  • It can be operated from the PC (software included)
  • Specific algorithms are stored into the equipment and can be recall at any time
  • Operator Name and Product Lot number entry using Computer
  • Auto-calibration with external Reference dipstick